{"id":1560,"date":"2016-01-11T11:43:56","date_gmt":"2016-01-11T13:43:56","guid":{"rendered":"http:\/\/fogo.lt\/new\/?p=1560"},"modified":"2016-01-11T11:43:56","modified_gmt":"2016-01-11T13:43:56","slug":"dumu-uzuolaidos-kas-tai-2","status":"publish","type":"post","link":"https:\/\/fogo.lt\/en\/dumu-uzuolaidos-kas-tai-2\/","title":{"rendered":"D\u016bm\u0173 u\u017euolaidos. Kas tai?"},"content":{"rendered":"<p>D\u016bm\u0173 u\u017euolaidas galime vadinti vienu i\u0161 svarbiausi\u0173 d\u016bm\u0173 \u0161alinimo sistemos element\u0173. Pagal standart\u0105 LST EN 12101-1 \u201cD\u016bm\u0173 ir \u0161ilumos valdymo sistemos. 1 dalis. D\u016bm\u0173 u\u017etvaroms keliami techniniai reikalavimai\u201c d\u016bm\u0173 u\u017euolaida vadinamas barjeras stabdantis gaisro d\u016bm\u0173 ir duj\u0173 sklaid\u0105 statinyje.<\/p>\n<p><u>Tipiniai u\u017edaviniai:<\/u><\/p>\n<p>&#8211; D\u016bm\u0173 rezervuaro suk\u016brimas stabdant ir ribojant d\u016bm\u0173 jud\u0117jim\u0105;<\/p>\n<p>&#8211; Kryptingo d\u016bm\u0173 jud\u0117jimo projektavimas;<\/p>\n<p>&#8211; D\u016bm\u0173 ar duj\u0173 plitimo \u012f kitas zonas ribojimas arba \u0161io veiksnio u\u017edelsimas.<\/p>\n<p>D\u016bm\u0173 u\u017euolaid\u0173 tipai:<\/p>\n<p>Stacionarios d\u016bm\u0173 u\u017euolaidos, tipas <strong>SSB<\/strong> (static smoke barriers). Sumontuota tam tikro dyd\u017eio u\u017euolaida i\u0161laikanti savo dyd\u017eio parametrus ir \u201cramyb\u0117s b\u016bsenos\u201d, ir gaisro metu. D\u0117mesio: statinio konstrukcijos gali b\u016bti panaudojamos kaip stacionarios d\u016bm\u0173 u\u017euolaidos. Jos taip pat gali b\u016bti didinamos papildom\u0173 stacionari\u0173 ar mobili\u0173 u\u017euolaid\u0173 pagalba, ta\u010diau privalo atitikti standarto LST EN 12101-1 reikalavimus. Da\u017eniausiai gaminamos pvz. i\u0161 A1\/A2 degumo klas\u0117s plok\u0161\u010di\u0173, metalo, stiklo.<\/p>\n<p>Aktyvios d\u016bm\u0173 u\u017euolaidos, tipas <strong>ASB<\/strong> (active smoke barriers). Tai u\u017euolaida kuri ramyb\u0117s b\u016bsenoje b\u016bna susukta (kabo pritvirtinta prie perdangos plok\u0161t\u0117s), o gavusi atitinkam\u0105 signal\u0105 apie gaisro pavoj\u0173 i\u0161siskleid\u017eia iki suprojektuoto dyd\u017eio, auk\u0161\u010dio.<\/p>\n<p>U\u017euolaidos leid\u017eia kontroliuoti d\u016bm\u0173 jud\u0117jim\u0105 gaisro metu ir neabejotinai tampa vienu pagrindiniu d\u016bm\u0173 \u0161alinimo sistemos akcentu. Kod\u0117l gi jos tokios svarbios??<\/p>\n<p>Sakykime, d\u016bm\u0173 u\u017euolaidos b\u016bt\u0173 blogai suprojektuotos arba parinktos, t.y:<\/p>\n<p>&#8211; Jeigu jos nei\u0161siskleis iki reikiamo dyd\u017eio (plo\u010dio ar auk\u0161\u010dio), kaip suprojektuota gaisro scenarijuje (aktyvi\u0173 u\u017euolaid\u0173 atveju),<\/p>\n<p>&#8211; Jeigu j\u0173 d\u016bm\u0173 izoliacijos savyb\u0117s (leid\u017eiamas d\u016bm\u0173 prasiskverbimas per u\u017euolaid\u0105) nebus patikrintos pagal standart\u0105 LST EN 12101-1,<\/p>\n<p>\u2026tai sumontuoti sekantys d\u016bm\u0173 \u0161alinimo elementai (tokie kaip: prie\u0161g liukai, ventiliatoriai) priklausomai nuo priimto kar\u0161\u010dio ir d\u016bm\u0173 \u0161alinimo scenarijaus (gravitacin\u0117, mechanin\u0117), nesugeb\u0117s atlikti savo u\u017eduo\u010di\u0173 kurioms buvo suprojektuoti ir sumontuoti.<\/p>\n<p>Tai rei\u0161kia, kad reikalaujamas d\u016bm\u0173 storis nuo perdangos nebus u\u017etikrintas, temperat\u016bros kilimo kreiv\u0117 kils nekontroliuojama ir atsiras pavojus besievakuojantiems \u017emon\u0117ms (jau nekalbant apie gaisro plitimo auk\u0161te pavoj\u0173).<\/p>\n<p>Ta\u010diau priimkime toki\u0105 situacij\u0105, kad d\u016bm\u0173 u\u017euolaidos suveik\u0117, o likusios d\u016bm\u0173 \u0161alinimo sistemos dalys d\u0117l ka\u017ekoki\u0173 prie\u017eas\u010di\u0173 neveikia. Net tokiu atveju, d\u016bm\u0173 u\u017euolaidos sudaro nat\u016bral\u0173 d\u016bm\u0173 ir kar\u0161t\u0173 duj\u0173 rezervuar\u0105 stabdant ar u\u017edelsiant j\u0173 plitim\u0105. Jos u\u017etikrin\u0105 papildom\u0105 saugumo rezerv\u0105 didindamos besievakuojan\u010di\u0173 \u017emoni\u0173 \u0161ans\u0105 saugiai palikti pavojing\u0105 zon\u0105. \u0160tai i\u0161 kur atsiranda poreikis d\u016bm\u0173 u\u017euolaidoms.<\/p>\n<p>Bendrai kalbant, d\u016bm\u0173 u\u017euolaidos privalo atitikti dviems pagrindiniams reikalavimams:<\/p>\n<p>&#8211; Sandarumas d\u016bmams, apra\u0161omas kaip maksimalus d\u016bm\u0173 nuotekio lygis 25m<sup>3<\/sup>\/h\/m<sup>2<\/sup>. Tyrimai atliekami prie kambario ir 200 <sup>0<\/sup>C temperat\u016bros kei\u010diant sl\u0117g\u012f.<\/p>\n<p>&#8211; Atsparumas (sandarumas) ugniai, rei\u0161kia izoliacij\u0105 liepsnoms ir \u012fkaitusioms dujoms bandan\u010dioms prasibrauti \u012f nekaitinam\u0105 pus\u0119 i\u0161rei\u0161kiamas parametrais D arba DH. D rei\u0161kia atsparum\u0105 ugniai prie 600 <sup>0<\/sup>C temperat\u016bros bandymo metu, DH rei\u0161kia atsparum\u0105 ugniai sugrie\u017etintomis s\u0105lygomis vir\u0161 600 <sup>0<\/sup>C temperat\u016bros, pagal standartin\u0119 gaisro kreiv\u0119 bandymo metu;<\/p>\n<p>Da\u017eniausiai d\u016bm\u0173 u\u017euolaidos montuojamos prie statinio konstrukcij\u0173 taip, kad u\u017etikrint\u0173 ribines vertes (gaisro temperat\u016bra, jos kilimo intensyvumas). Tai reikalauja bendro architekto ir gaisrin\u0117s saugos in\u017einieriaus darbo, nustatant d\u016bm\u0173 u\u017euolaidos prie\u0161gaisrinius parametrus (atsparumas ugniai D arba DH) ir laiko (i\u0161reik\u0161to minut\u0117mis) kur\u012f jie privalo b\u016bti u\u017etikrinti pagal standarto LST EN 12101-1 reikalavimus.<\/p>\n<p>Reikia sutikti jog \u0161iuo metu statybose tenka matyti nema\u017eai i\u0161 plieno skardos sumontuot\u0173 d\u016bm\u0173 u\u017euolaid\u0173. Jos es\u0105 atitinka \u0161iuo metu galiojant\u012f EI 15 atsparumo ugniai reikalavim\u0105. Noriu \u012fsp\u0117ti ypa\u010d technin\u0117s prie\u017ei\u016bros atstovus jog da\u017eniausiai tokio tipo pertvar\u0117l\u0117s bandymo metu jau po 5 minu\u010di\u0173 deformuojasi ir realios naudos neatlieka. Profiliuotos skardos, kuri\u0105 da\u017eniausiai tenka matyti statybose nerekomenduoju naudoti vienos. Per savo gaisrin\u0117s saugos in\u017einieriaus patirt\u012f dar n\u0117karto nema\u010diau teising\u0173 atitikties dokument\u0173 tokio tipo \u201cd\u016bm\u0173 u\u017euolaidai. Atei\u010diai rekomenduoju atid\u017eiau \u017evelgti \u012f prie\u0161gaisrini\u0173 sistem\u0173 atitikties dokumentus ir i\u0161siai\u0161kinti ar jos i\u0161bandytos pagal reikiamus standartu<\/p>\n","protected":false},"excerpt":{"rendered":"<p>D\u016bm\u0173 u\u017euolaidas galime vadinti vienu i\u0161 svarbiausi\u0173 d\u016bm\u0173 \u0161alinimo sistemos element\u0173. Pagal standart\u0105 LST EN 12101-1 \u201cD\u016bm\u0173 ir \u0161ilumos valdymo<\/p>\n","protected":false},"author":1,"featured_media":1289,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[2],"tags":[],"_links":{"self":[{"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/posts\/1560"}],"collection":[{"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/comments?post=1560"}],"version-history":[{"count":0,"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/posts\/1560\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/media\/1289"}],"wp:attachment":[{"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/media?parent=1560"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/categories?post=1560"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fogo.lt\/en\/wp-json\/wp\/v2\/tags?post=1560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}